Siemens SIPROTEC 5 7SL82 Distance Protection Relay

از {{model.count}} نظر
comparison
Specifications
Technical Specifications
Differential and distance protection for medium and subtransmission systems ، Interoperable with SIPROTEC 5 and SIPROTEC 4 devices ، 3-pole tripping, minimum tripping time: 19 ms ، Inputs: 4 current transformers, 4 voltage transformers (optional) ، 11 or 23 binary inputs, 9 or 16 binary outputs ، Modular hardware design (1/3 base module, no 1/6 expansion) ، Available with large or small display ، Housing width: 1/3 × 19 inches ، Standard conformal coating ، Suitable for line protection at all voltage levels ، Detects ground faults in isolated or arc-suppression-coil systems ، Communication via optical fiber, two-wire or network connections ، Integrated Phasor Measurement Unit (PMU)
  • {{value}}
Product inquiry
Available in stock

Available in stock

Fast shipping

Fast shipping

Product authenticity guarantee

Product authenticity guarantee

The SIPROTEC 7SL82 Distance Protection Relay provides advanced differential and distance protection for medium and high-voltage systems. Equipped with 4 current and 4 voltage inputs, 3-pole tripping, and flexible communication options, it ensures fast, precise, and reliable protection for industrial and utility networks in Mumbai
Technical Specifications
Differential and distance protection for medium and subtransmission systems
Interoperable with SIPROTEC 5 and SIPROTEC 4 devices
3-pole tripping, minimum tripping time: 19 ms
Inputs: 4 current transformers, 4 voltage transformers (optional)
11 or 23 binary inputs, 9 or 16 binary outputs
Modular hardware design (1/3 base module, no 1/6 expansion)
Available with large or small display
Housing width: 1/3 × 19 inches
Standard conformal coating
Suitable for line protection at all voltage levels
Detects ground faults in isolated or arc-suppression-coil systems
Communication via optical fiber, two-wire or network connections
Integrated Phasor Measurement Unit (PMU)