The Siemens Reyrolle 7SR210 “Argus” is a non-directional overcurrent protection relay designed for modern feeder applications. With 4xI inputs, it provides precise non-directional overcurrent detection, ensuring reliable protection for industrial, commercial, and utility networks. This relay is ideal for upgrading protection systems or replacing existing relays, offering advanced functionality and seamless SCADA integration
Technical Specifications
Non-directional overcurrent protection with 4xI inputs
Industrial-grade reliability for feeder circuits
Protection Functions: Undercurrent (37), Broken Conductor (46BC), Negative Phase Sequence Overcurrent (46NPS), Thermal Overload (49), Overcurrent (50,51), Earth Fault (50G,50N,50SEF,51G,51N,51SEF), Directional Control (67), High Impedance REF (64H), Under/Over Voltage (27/59), Negative Phase Sequence Voltage (47), Voltage Controlled Overcurrent (51V), Neutral Voltage Displacement (59N), Under/Over Frequency (81)
Supervision Functions: CT Supervision (60CTS), Trip & Close Circuit Supervision (74T/CCS), VT Supervision (60VTS), Inrush Detector (81HBL2), Circuit Breaker Fail (50BF)
Control Functions: Auto Reclose (79)
Monitoring Functions: Primary/Secondary Currents and Earth, Line and Phase Voltages, Apparent Power & Power Factor, Real & Reactive Power, Wh & VArh Forward/Reverse, Historical Demand Records, PPS/NPS/ZPS Voltages & Currents
Authorized Siemens product with competitive pricing, local stock, and technical support in Mumbai
Industrial-grade reliability for feeder circuits
Protection Functions: Undercurrent (37), Broken Conductor (46BC), Negative Phase Sequence Overcurrent (46NPS), Thermal Overload (49), Overcurrent (50,51), Earth Fault (50G,50N,50SEF,51G,51N,51SEF), Directional Control (67), High Impedance REF (64H), Under/Over Voltage (27/59), Negative Phase Sequence Voltage (47), Voltage Controlled Overcurrent (51V), Neutral Voltage Displacement (59N), Under/Over Frequency (81)
Supervision Functions: CT Supervision (60CTS), Trip & Close Circuit Supervision (74T/CCS), VT Supervision (60VTS), Inrush Detector (81HBL2), Circuit Breaker Fail (50BF)
Control Functions: Auto Reclose (79)
Monitoring Functions: Primary/Secondary Currents and Earth, Line and Phase Voltages, Apparent Power & Power Factor, Real & Reactive Power, Wh & VArh Forward/Reverse, Historical Demand Records, PPS/NPS/ZPS Voltages & Currents
Authorized Siemens product with competitive pricing, local stock, and technical support in Mumbai
You too can leave a comment about this product